Hey there! As a supplier of 35 type current transformers, I've seen my fair share of issues with these devices. In this blog, I'll be talking about the common faults of a 35 type current transformer and what you can do to prevent them.
First off, let's understand what a 35 type current transformer is. It's a crucial component in electrical systems, used to measure and monitor electrical current. They step down high currents to a level that can be safely measured by meters and relays. But like any electrical device, they're prone to certain faults.
1. Insulation Failure
One of the most common faults in a 35 type current transformer is insulation failure. Over time, the insulation materials can degrade due to factors like heat, moisture, and electrical stress. When the insulation breaks down, it can lead to short - circuits, which are not only dangerous but can also cause significant damage to the transformer and other connected equipment.
Moisture is a major culprit here. If the transformer is installed in a damp environment or there's a leak in the enclosure, water can seep into the insulation. This reduces its dielectric strength and increases the risk of electrical breakdown. To prevent this, it's important to ensure proper installation in a dry location and use high - quality insulation materials.
Another cause of insulation failure is overheating. Continuous operation at high temperatures can cause the insulation to dry out and become brittle. This makes it more susceptible to cracking and breakdown. Regular monitoring of the transformer's temperature can help detect early signs of overheating. You can use temperature sensors to keep track of the temperature and take corrective action if it exceeds the safe limits.
2. Turns Ratio Errors
The turns ratio of a current transformer is the ratio of the number of turns in the primary winding to the number of turns in the secondary winding. A turns ratio error occurs when the actual ratio deviates from the designed ratio. This can happen due to manufacturing defects, mechanical damage, or changes in the magnetic properties of the core.
Manufacturing defects can include incorrect winding of the coils or variations in the number of turns. Even a small error in the number of turns can lead to significant inaccuracies in current measurement. Mechanical damage, such as a physical impact on the transformer, can also cause the turns ratio to change. For example, if the windings are displaced or damaged, the magnetic coupling between the primary and secondary coils is affected.
Changes in the magnetic properties of the core can also result in turns ratio errors. Factors like temperature, humidity, and aging can alter the magnetic permeability of the core material. This affects the way the magnetic flux is transferred between the windings and leads to inaccurate current transformation. To minimize turns ratio errors, it's essential to perform regular calibration of the current transformer.
3. Core Saturation
Core saturation is another common problem in 35 type current transformers. The core of a current transformer is made of a magnetic material, usually iron. When the magnetic field in the core reaches a certain level, the core becomes saturated. This means that it can no longer increase its magnetic flux density in proportion to the increase in the primary current.


During core saturation, the secondary current no longer accurately represents the primary current. This can lead to incorrect current measurements and can also cause problems with protective relays. For example, if a protective relay is relying on the secondary current from a saturated current transformer, it may not operate correctly in the event of a fault.
Core saturation can be caused by high - fault currents, incorrect selection of the transformer's rating, or a low - impedance load on the secondary side. To avoid core saturation, it's important to select a current transformer with an appropriate rating for the expected primary current. You should also ensure that the secondary load impedance is within the specified range.
4. Secondary Open - Circuit
A secondary open - circuit in a current transformer is extremely dangerous. When the secondary circuit is open, the current in the secondary winding drops to zero. However, the primary current continues to flow, creating a very high magnetic field in the core. This high magnetic field can induce extremely high voltages in the secondary winding, which can damage the insulation and pose a serious safety hazard to personnel.
A secondary open - circuit can occur due to loose connections, broken wires, or faulty terminals. Regular inspection of the secondary circuit is necessary to detect and fix any potential issues. It's also important to use proper terminal blocks and ensure that all connections are tight and secure.
5. Noise and Vibration
Excessive noise and vibration in a 35 type current transformer can be a sign of a problem. Noise can be caused by magnetostriction, which is the change in the shape of the magnetic material in the core when it's magnetized. Vibration can be due to mechanical resonance, unbalanced magnetic forces, or loose components.
Magnetostriction causes the core to expand and contract slightly with each cycle of the alternating current. This can produce a humming sound. If the noise is excessive, it may indicate a problem with the core material or the magnetic circuit. Vibration can damage the internal components of the transformer over time. It can also cause loose connections and lead to other faults.
To reduce noise and vibration, it's important to use proper mounting techniques. The transformer should be securely mounted on a stable base to minimize vibrations. You can also use vibration - damping materials to absorb the vibrations.
Our Solutions
At our company, we offer a range of high - quality 35 type current transformers, such as the LZZBJ9 - 40.5type Current Transformer, LZZBJ9 - 35 Type Current Transformer, and LCZ - 35Q Current Transformer. These transformers are designed with the latest technology and high - quality materials to minimize the occurrence of the common faults mentioned above.
We also provide comprehensive after - sales service, including installation guidance, regular maintenance, and calibration. Our team of experts can help you select the right current transformer for your specific application and ensure its proper operation.
If you're in the market for a 35 type current transformer or have any questions about the faults and solutions, don't hesitate to reach out to us. We're here to assist you in making the best choice for your electrical system. Whether you need a transformer for a small - scale project or a large industrial application, we have the expertise and products to meet your needs.
References
- Electrical Power Systems Engineering Handbook, Second Edition
- Standards for Current Transformers by IEEE
- Handbook of Transformer Technology: Design, Technology, and Diagnostics