As a supplier of 20KA surge protection devices, I often encounter inquiries from customers about how to connect multiple such devices in series. This blog aims to provide a comprehensive guide on this topic, sharing professional knowledge and practical experience.
Understanding the Basics of Surge Protection Devices
Before delving into the series connection of 20KA surge protection devices, it's essential to understand what surge protection devices are and how they work. Surge protection devices (SPDs) are designed to protect electrical systems and equipment from transient over - voltages, such as those caused by lightning strikes or switching operations. A 20KA surge protection device can handle a surge current of up to 20KA, which is suitable for many medium - sized electrical systems.
Reasons for Connecting Multiple 20KA Surge Protection Devices in Series
There are several reasons why one might choose to connect multiple 20KA surge protection devices in series:
- Enhanced Protection: By connecting multiple SPDs in series, the overall protection level can be improved. Each device can further reduce the surge voltage, providing a more comprehensive safeguard for the connected equipment.
- Meeting Specific Requirements: In some cases, the electrical system may have specific requirements for surge protection that a single 20KA SPD cannot meet. Series connection can help to meet these requirements.
- Redundancy: Series connection provides a certain degree of redundancy. If one SPD fails, the others can still provide some level of protection.
Steps for Connecting Multiple 20KA Surge Protection Devices in Series
Step 1: Select the Right Devices
When choosing 20KA surge protection devices for series connection, it's crucial to ensure that they are compatible with each other. Consider factors such as the rated voltage, response time, and discharge capacity. For example, our CHT1 - D10 KA Surge Protection Device and CHT1 - R Fuse Protection Series Surge Protector can be used in combination with 20KA SPDs in some applications.
Step 2: Determine the Connection Order
The order of connection is important. Generally, the device with a faster response time should be placed closer to the power source. This allows it to quickly respond to the surge and reduce the voltage before it reaches the subsequent devices.


Step 3: Prepare the Installation Site
Make sure the installation site is clean, dry, and well - ventilated. The electrical panel or distribution board where the SPDs will be installed should be properly grounded. The grounding resistance should meet the relevant standards.
Step 4: Connect the Devices
- Power Disconnection: Before installation, disconnect the power supply to ensure safety.
- Wiring: Connect the input terminal of the first 20KA SPD to the power source. Then, connect the output terminal of the first SPD to the input terminal of the second SPD. Repeat this process for all the SPDs in the series. Use appropriate wiring materials with sufficient cross - sectional area to ensure low - resistance connections.
- Grounding: Connect the grounding terminals of all the SPDs to the grounding system. A good grounding connection is essential for the proper functioning of the surge protection devices.
Step 5: Testing and Commissioning
After installation, conduct a series of tests to ensure that the connected SPDs are working properly. Use a surge tester to simulate surge events and measure the voltage and current at different points in the system. Check for any signs of abnormal operation, such as overheating or short - circuits.
Precautions When Connecting Multiple 20KA Surge Protection Devices in Series
- Voltage Sharing: When multiple SPDs are connected in series, proper voltage sharing between the devices must be ensured. Uneven voltage sharing can lead to over - stress on some devices and premature failure.
- Coordination: The coordination between the SPDs is crucial. The response time and discharge capacity of each device should be carefully coordinated to ensure that they work together effectively.
- Maintenance: Regular maintenance is necessary for the series - connected SPDs. Check the devices periodically for signs of damage, such as burnt components or loose connections. Replace any faulty devices promptly.
Applications of Series - Connected 20KA Surge Protection Devices
Series - connected 20KA surge protection devices are widely used in various applications:
- Industrial Facilities: In industrial plants, where there are a large number of electrical equipment and sensitive control systems, series - connected SPDs can provide reliable protection against lightning and switching surges.
- Commercial Buildings: Office buildings, shopping malls, and hotels often have complex electrical systems. Series - connected SPDs can help to protect the electrical infrastructure and ensure the normal operation of the equipment.
- Telecommunication Stations: Telecommunication stations are highly sensitive to surges. Series - connected 20KA SPDs can protect the communication equipment from damage caused by lightning strikes.
Comparison with Other Connection Methods
Compared with parallel connection, series connection has its own advantages and disadvantages. In parallel connection, multiple SPDs share the surge current, which can increase the overall discharge capacity. However, series connection can provide better voltage reduction and enhanced protection in some cases. Our CHT1 - B60KA Surge Protection Device can be used in parallel or series depending on the specific requirements of the system.
Conclusion
Connecting multiple 20KA surge protection devices in series is a complex but effective way to enhance surge protection. By following the steps and precautions outlined in this blog, you can ensure a safe and reliable installation. If you have any questions about surge protection or need assistance with the selection and installation of our 20KA surge protection devices, please feel free to contact us for further consultation and procurement discussions. We are committed to providing high - quality products and professional services to meet your surge protection needs.
References
- IEC 61643 - 11: Low - voltage surge protective devices - Part 11: Surge protective devices connected to low - voltage power systems - Requirements and tests.
- IEEE C62.41.2: Recommended Practice on Characterization of Surges in Low - Voltage (1000 V and Less) AC Power Circuits.
- UL 1449: Standard for Surge Protective Devices.