video
LZZBJ9-10 B Current Transformer

LZZBJ9-10 B Current Transformer

LZZBJ9-10 B current transformer is epoxy resin casting insulation closed indoor type products, applicable to 10 kv and below, current of ac 50 hz lines, electric energy measurement and relay protection.

Product Introduction

product Introduction

 

LZZBJ9-10 B current transformer is epoxy resin casting insulation closed indoor type products, applicable to 10 kv and below, current of ac 50 hz lines, electric energy measurement and relay protection.

 

Types of meaning

product-259-128

 

 

Conditions of use

 

1. The altitude does not exceed 1000 m

2. The ambient temperature is not higher than + 40 ℃, no less than 5 ℃

3. The surrounding air relative humidity is not greater than 90% (20 ℃)

4. Installation site had no serious effect of transformer insulation gas, steam, chemical deposition, filthy and other explosive or corrosive media

5. Installation site without severe vibration and turbulence

 

Introduction of the structure

 

Pillar type the current transformer is fully enclosed structure, using circular iron core coil, the primary and secondary coil with resin casting molding. Due to the strengthened insulation, under the condition of moisture condensation and secondary filth is normal operation.

 

Overall dimensions

 

product-468-672

 

Product s sign: once a P1, P2 and secondary students' 1 S1, S2, 1 to 2 b S1, S2, 2 when an electric current from P1 to P2, the secondary current by S1 flow by the external loop to S2, is subtractive polarity. When a current through the, secondary loop shall not open, otherwise a high voltage is generated 

 

Technical Parameters

 

Model

Rated primary current

Accuracy level combination

Rated output

Short-time thermal current

Rated dynamic stability current

LZZBJ9-10B

10

0.2S/10P10(15)

10/15

2.0

5.0

0.5S/10P10(15)

10/15

2.0

5.0

0.2/10P10(15)

10/15

1.0

2.5

0.5/10P10(15)

15/15

1.0

2.5

15

0.2S/10P10(15)

10/15

4.5

11.25

0.5S/10P10(15)

10/15

4.5

11.25

0.2/10P10(15)

10/15

1.5

3.75

0.5/10P10(15)

15/15

1.5

3.75

20

0.2S/10P10(15)

10/15

6

15

0.5S/10P10(15)

10/15

6

15

0.2/10P10(15)

10/15

3

7.5

0.5/10P10(15)

15/15

3

7.5

30

0.2S/10P10(15)

10/15

12

30

0.5S/10P10(15)

10/15

12

30

0.2/10P10(15)

10/15

4.5

11.25

0.5/10P10(15)

15/15

4.5

11.25

0.2/10P20

10/15

3.6

9

0.5/10P20

10/15

3.6

9

40

0.2S/10P10(15)

10/15

16

40

0.5S/10P10(15)

10/15

16

40

0.2/10P15

15/15

6

15

0.5/10P15

15/15

6

15

0.2/10P20

10/15

4.8

12

0.5/10P20

10/15

4.8

12

50

0.2S/10P10(15)

10/15

21

52.5

0.5S/10P10(15)

10/15

21

52.5

0.2/10P10(15)

15/15

7.5

18.75

0.5/10P10(15)

15/15

7.5

18.75

0.2/10P20

10/15

6

15

0.5/10P20

10/15

6

15

60

0.2S/10P10(15)

10/15,10/20

21

52.5

0.5S/10P10(15)

10/15,10/20

21

52.5

0.2/10P10(15)

15/15,10/20

9

22.5

 

Model

Rated primary current

Accuracy level combination

Rated output

Short-time thermal current

Rated dynamic stability current

LZZBJ9-10B

60

0.5/10P10(15)

15/15, 20/20

9

22.5

0.2/10P20

10/15

7.2

18

0.5/10P20

10/15

7.2

18

75

0.2S/10P10(15)

10/15

31.5

78.75

0.5S/10P10(15)

10/15

31.5

78.75

0.2/10P10(15)

15/15

10

25

0.5/10P10(15)

15/15

10

25

0.2/10P20

10/15

9

22.5

0.5/10P20

10/15

9

22.5

100

0.2S/10P10(15)

10/15

4

112.5

0.5S/10P10(15)

10/15

45

112.5

0.2/10P10(15)

10/15

21

52.5

0.5/10P10(15)

15/15

21

52.5

0.2/10P20

10/15

12

30

0.5/10P20

10/15

12

30

150

0.2S/10P10(15)

10/15

45

112.5

0.5S/10P10(15)

10/15

45

112.5

0.2/10P10(15)

10/15

31.5

78,75

0.5/10P10(15)

15/15

31.5

78,75

0.2/10P20

10/15

18

45

0.5/10P20

10/15

18

45

200,250

0.2S/10P10(15)

10/15

45

112.5

0.5S/10P10(15)

10/15

45

112.5

0.2/10P10(15)

10/15

45

112.5

0.5/10P10(15)

15/15

45

112.5

0.2/10P20

10/15

24

60

0.5/10P20

10/15

24

60

300

0.2S/10P10(15)

10/15

63

157.5

0.5S/10P10(15)

10/15

63

157.5

0.2/10P10(15)

10/15

45

112.5

0.5/10P10(15)

15/15

45

112.5

0.2/10P20

10/15

36

90

0.5/10P20

10/15

36

90

400

0.2S/10P10(15)

10/15

63

157.5

0.5S/10P10(15)

10/15

63

157.5

0.2/10P10(15)

10/15

63

157.5

0.5/10P10(15)

15/20

63

157.5

0.2/10P20

10/15

48

120

0.5/10P20

10/15

48

120

500

0.2S/10P10(15)

15/20

63

157.5

0.5S/10P10(15)

15/20

63

157.5

0.2/10P10(15)

15/20

63

157.5

 

Model

Rated primary current

Accuracy level combination

Rated output

Short-time thermal current

Rated dynamic stability current

LZZBJ9-10B

500

0.5/10P10(15)

20/20

63

157.5

0.2/10P20

15/15

63

157.5

0.5/10P20

15/15

63

157.5

600
800
1000

0.2S/10P10(15)

15/20

63

130

0.5S/10P10(15)

15/20

63

130

0.2/10P10(15)

15/20

63

130

0.5/10P10(15)

20/20

63

130

0.2/10P20

15/15

63

130

0.5/10P20

15/15

63

130

1200
1500
2000

0.2S/10P10(15)

15/20

80

160

0.5S/10P10(15)

15/20

80

160

0.2/10P10(15)

15/20

80

160

0.5/10P10(15)

20/20

80

160

0.2/10P20

15/20

80

160

0.5/10P20

15/20

80

160

2500

0.2S/10P10(15)

15/30

80

160

0.5S/10P10(15)

15/30

100

200

0.2/10P10(15)

15/20

100

200

0.5/10P10(15)

15/20

100

200

0.2/10P20

20/20

100

200

0.5/10P20

15/20

100

200

3000

0.2S/10P10(15)

15/20

100

200

0.5S/10P10(15)

15/30

100

200

0.2/10P10(15)

15/20

100

200

0.5/10P10(15)

20/20

100

200

0.2/10P20

15/20

100

200

0.5/10P20

15/20

100

200

 

LZZBJ9-10B Current Transformer Operation Notes

 

①The secondary side of B current transformer must not be open during operation. Once the secondary side is open, it will burn due to excessive iron loss and high temperature, or the voltage of the secondary winding will increase and the insulation will be broken, resulting in the danger of high-voltage electric shock. Therefore, when changing instruments, such as replacing ammeters, active meters, reactive meters, etc., the current circuit should be short-circuited before changing the metering instrument. When the meter is adjusted, it should be connected to the secondary circuit first, then the short-circuit wire should be removed and the meter should be checked to see if it is normal.

②If sparks are found when removing the short-circuit wire, the current transformer is open at this time, and it should be short-circuited again immediately. When it is found that there is no open circuit in the metering instrument circuit, the short-circuit wire can be removed again. When removing the short-circuit of the current transformer, you should stand on the insulating leather pad. In addition, you should consider disabling the protection device of the current transformer circuit. After the work is completed, the protection device can be put into operation.

③ If the current transformer makes a buzzing sound, check whether the internal core is loose and tighten the core bolts. The shell of the secondary side of the current transformer must be reliably grounded.

④ When the insulation resistance of the secondary side coil of the current transformer is lower than 10~20 megohms, it must be dried to restore the insulation before use.

 

ABOUT US

 

Quality sales:The company has a modern enterprise management and scientific research personnel. The products have passed the ISO9000 system certification, the national compulsory certification measurement and certification MC, the export CE, and the lightning protection products are filed in various provinces across the country. At the same time, they have imported advanced foreign inspection equipment and strictly controlled the quality. The company's products have been well received by new and old customers.

Tengtai International Electric, based on more than 30 countries and regions such as the United States/UK/France/Spain, is not only a product but also a quality.

 

4

5

1

2

 

152619443cc4a2e63edc4501df150b4e1

Hot Tags: lzzbj9-10 b current transformer, China lzzbj9-10 b current transformer suppliers, 10kv current transformer for power plants, 10 current transformer, high voltage transformer to sense current at 10kv, current transformer for 10kv power transmission, A current transformer, C current transformer

Send Inquiry

whatsapp

Phone

E-mail

Inquiry

Bag